Compare commits

..

3 Commits

7 changed files with 516 additions and 2 deletions

View File

@@ -32,6 +32,32 @@
} }
] ]
}, },
{
"name": "Flow",
"models": [
{
"name": "VegaFlow 10",
"units": ["m³/h", "gpm", "l/min"]
},
{
"name": "VegaFlow 20",
"units": ["m³/h", "gpm", "l/min"]
}
]
},
{
"name": "Level",
"models": [
{
"name": "VegaLevel 10",
"units": ["m", "ft", "mm"]
},
{
"name": "VegaLevel 20",
"units": ["m", "ft", "mm"]
}
]
},
{ {
"name": "Level", "name": "Level",
"models": [ "models": [
@@ -68,6 +94,36 @@
] ]
} }
] ]
},
{
"name": "Binder Engineering",
"categories": [
{
"name": "Valves",
"types": [
{
"name": "Gate",
"models": [
{
"id": "binder-valve-001",
"name": "ECDV",
"units": ["m³/h", "gpm", "l/min"]
}
]
},
{
"name": "Jet",
"models": [
{
"id": "binder-valve-002",
"name": "JCV",
"units": ["m³/h", "gpm", "l/min"]
}
]
}
]
}
]
} }
] ]
} }

View File

@@ -0,0 +1,16 @@
{
"1.204": {
"125": {
"x": [0,10,20,30,40,50,60,70,80,90,100],
"y": [0,18,50,95,150,216,337,564,882,1398,1870]
},
"150": {
"x": [0,10,20,30,40,50,60,70,80,90,100],
"y": [0,25,73,138,217,314,490,818,1281,2029,2715]
},
"400": {
"x": [0,10,20,30,40,50,60,70,80,90,100],
"y": [0,155,443,839,1322,1911,2982,4980,7795,12349,16524]
}
}
}

View File

@@ -16,7 +16,7 @@ const configUtils = require('./src/helper/configUtils.js');
// Domain-specific modules // Domain-specific modules
const { MeasurementContainer } = require('./src/measurements/index.js'); const { MeasurementContainer } = require('./src/measurements/index.js');
const configManager = require('./src/configs/index.js'); const configManager = require('./src/configs/index.js');
const nrmse = require('./src/nrmse/errorMetrics.js'); const nrmse = require('./src/nrmse/ErrorMetrics.js');
const state = require('./src/state/state.js'); const state = require('./src/state/state.js');
const convert = require('./src/convert/index.js'); const convert = require('./src/convert/index.js');
const MenuManager = require('./src/menu/index.js'); const MenuManager = require('./src/menu/index.js');

387
src/configs/valve.json Normal file
View File

@@ -0,0 +1,387 @@
{
"general": {
"name": {
"default": "valve",
"rules": {
"type": "string",
"description": "A human-readable name or label for this machine configuration."
}
},
"id": {
"default": null,
"rules": {
"type": "string",
"nullable": true,
"description": "A unique identifier for this configuration. If not provided, defaults to null."
}
},
"unit": {
"default": "m3/h",
"rules": {
"type": "string",
"description": "The default measurement unit for this configuration (e.g., 'meters', 'seconds', 'unitless')."
}
},
"logging": {
"logLevel": {
"default": "info",
"rules": {
"type": "enum",
"values": [
{
"value": "debug",
"description": "Log messages are printed for debugging purposes."
},
{
"value": "info",
"description": "Informational messages are printed."
},
{
"value": "warn",
"description": "Warning messages are printed."
},
{
"value": "error",
"description": "Error messages are printed."
}
]
}
},
"enabled": {
"default": true,
"rules": {
"type": "boolean",
"description": "Indicates whether logging is active. If true, log messages will be generated."
}
}
}
},
"functionality": {
"softwareType": {
"default": "valve",
"rules": {
"type": "string",
"description": "Specified software type for this configuration."
}
},
"role": {
"default": "controller",
"rules": {
"type": "string",
"description": "Indicates the role this configuration plays within the system."
}
},
"positionVsParent":{
"default":"atEquipment",
"rules": {
"type": "enum",
"values": [
{
"value": "atEquipment",
"description": "The node is connected at the equipment level and is responsible for controlling or monitoring the equipment as a whole."
},
{
"value": "upstream",
"description": "The node is connected in a downstream position, indicating it is responsible for monitoring or controlling processes that occur after the equipment's operation, such as product flow or output."
},
{
"value": "downstream",
"description": "The node is connected in an upstream position, indicating it is responsible for monitoring or controlling processes that occur before the equipment's operation, such as input flow or supply."
}
],
"description": "Defines the position of the measurement relative to its parent equipment or system."
}
}
},
"asset": {
"uuid": {
"default": null,
"rules": {
"type": "string",
"nullable": true,
"description": "A universally unique identifier for this asset. May be null if not assigned."
}
},
"tagCode":{
"default": null,
"rules": {
"type": "string",
"nullable": true,
"description": "Asset tag code which is a unique identifier for this asset. May be null if not assigned."
}
},
"geoLocation": {
"default": {},
"rules": {
"type": "object",
"description": "An object representing the asset's physical coordinates or location.",
"schema": {
"x": {
"default": 0,
"rules": {
"type": "number",
"description": "X coordinate of the asset's location."
}
},
"y": {
"default": 0,
"rules": {
"type": "number",
"description": "Y coordinate of the asset's location."
}
},
"z": {
"default": 0,
"rules": {
"type": "number",
"description": "Z coordinate of the asset's location."
}
}
}
}
},
"supplier": {
"default": "Unknown",
"rules": {
"type": "string",
"description": "The supplier or manufacturer of the asset."
}
},
"category": {
"default": "valve",
"rules": {
"type": "string",
"description": "A general classification of the asset tied to the specific software. This is not chosen from the asset dropdown menu."
}
},
"type": {
"default": "gate",
"rules": {
"type": "string",
"description": "A more specific classification within 'type'. For example, 'centrifugal' for a centrifugal pump."
}
},
"model": {
"default": "Unknown",
"rules": {
"type": "string",
"description": "A user-defined or manufacturer-defined model identifier for the asset."
}
},
"unit": {
"default": "unitless",
"rules": {
"type": "string",
"description": "The unit of measurement for this asset (e.g., 'meters', 'seconds', 'unitless')."
}
},
"accuracy": {
"default": null,
"rules": {
"type": "number",
"nullable": true,
"description": "The accuracy of the machine or sensor, typically as a percentage or absolute value."
}
},
"valveCurve": {
"default": {
"1.204": {
"1": {
"x": [0, 10, 20, 30, 40, 50, 60, 70, 80, 90, 100],
"y": [0, 18, 50, 95, 150, 216, 337, 564, 882, 1398, 1870]
}
}
},
"rules": {
"type": "valveCurve",
"description": "the first parameter is kg (usually according to 1 normal cubic meter per hour acc. to din norm ) and the second parameter is the diameter in mm. The x values are the opening of the valve in percent and the y values are the KV values in m3/h. The KV value is the flow rate of water at a temperature of 20 degrees Celsius through the valve when it is fully open."
}
}
},
"mode": {
"current": {
"default": "auto",
"rules": {
"type": "enum",
"values": [
{
"value": "auto",
"description": "Machine accepts setpoints from a parent controller and runs autonomously."
},
{
"value": "virtualControl",
"description": "Controlled via GUI setpoints; ignores parent commands."
},
{
"value": "fysicalControl",
"description": "Controlled via physical buttons or switches; ignores external automated commands."
},
{
"value": "maintenance",
"description": "No active control from auto, virtual, or fysical sources."
}
],
"description": "The operational mode of the machine."
}
},
"allowedActions":{
"default":{},
"rules": {
"type": "object",
"schema":{
"auto": {
"default": ["statusCheck", "execMovement", "execSequence", "emergencyStop"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Actions allowed in auto mode."
}
},
"virtualControl": {
"default": ["statusCheck", "execMovement", "execSequence", "emergencyStop"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Actions allowed in virtualControl mode."
}
},
"fysicalControl": {
"default": ["statusCheck", "emergencyStop"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Actions allowed in fysicalControl mode."
}
},
"maintenance": {
"default": ["statusCheck"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Actions allowed in maintenance mode."
}
}
},
"description": "Information about valid command sources recognized by the machine."
}
},
"allowedSources":{
"default": {},
"rules": {
"type": "object",
"schema":{
"auto": {
"default": ["parent", "GUI", "fysical"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sources allowed in auto mode."
}
},
"virtualControl": {
"default": ["GUI", "fysical"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sources allowed in virtualControl mode."
}
},
"fysicalControl": {
"default": ["fysical"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sources allowed in fysicalControl mode."
}
}
},
"description": "Information about valid command sources recognized by the machine."
}
}
},
"source": {
"default": "parent",
"rules": {
"type": "enum",
"values": [
{
"value": "parent",
"description": "Commands are received from a parent controller."
},
{
"value": "GUI",
"description": "Commands are received from a graphical user interface."
},
{
"value": "fysical",
"description": "Commands are received from physical buttons or switches."
}
],
"description": "Information about valid command sources recognized by the machine."
}
},
"sequences":{
"default":{},
"rules": {
"type": "object",
"schema": {
"startup": {
"default": ["starting","warmingup","operational"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sequence of states for starting up the machine."
}
},
"shutdown": {
"default": ["stopping","coolingdown","idle"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sequence of states for shutting down the machine."
}
},
"emergencystop": {
"default": ["emergencystop","off"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sequence of states for an emergency stop."
}
},
"boot": {
"default": ["idle","starting","warmingup","operational"],
"rules": {
"type": "set",
"itemType": "string",
"description": "Sequence of states for booting up the machine."
}
}
}
},
"description": "Predefined sequences of states for the machine."
},
"calculationMode": {
"default": "medium",
"rules": {
"type": "enum",
"values": [
{
"value": "low",
"description": "Calculations run at fixed intervals (time-based)."
},
{
"value": "medium",
"description": "Calculations run when new setpoints arrive or measured changes occur (event-driven)."
},
{
"value": "high",
"description": "Calculations run on all event-driven info, including every movement."
}
],
"description": "The frequency at which calculations are performed."
}
}
}

View File

@@ -0,0 +1,29 @@
/**
* @file assertionUtils.js
*
* Utility functions for assertions and throwing errors in EVOLV.
*
* @description This module provides functions to assert conditions and throw errors when those conditions are not met.
* @exports ValidationUtils
*/
class Assertions {
/**
* Assert that no NaN values are present in an array.
* @param {Array} arr - The array to check for NaN values.
* @param {string} label - Array label to indicate where the error occurs.
*/
assertNoNaN(arr, label = "array") {
if (Array.isArray(arr)) {
for (const el of arr) {
assertNoNaN(el, label);
}
} else {
if (Number.isNaN(arr)) {
throw new Error(`NaN detected in ${label}!`);
}
}
}
}
module.exports = Assertions;

View File

@@ -83,6 +83,11 @@ class ChildRegistrationUtils {
this.connectValve(child); this.connectValve(child);
break; break;
case "machineGroup":
this.logger.debug(`Registering complete machineGroup child: ${id}`);
this.connectMachineGroup(child);
break;
case "actuator": case "actuator":
this.logger.debug(`Registering linear actuator child: ${id}`); this.logger.debug(`Registering linear actuator child: ${id}`);
this.connectActuator(child,positionVsParent); this.connectActuator(child,positionVsParent);
@@ -184,6 +189,26 @@ class ChildRegistrationUtils {
this.logger.info(`Valve ${valveId} registered successfully.`); this.logger.info(`Valve ${valveId} registered successfully.`);
} }
connectMachineGroup(machineGroup) {
if (!machineGroup) {
this.logger.warn("Invalid machineGroup provided.");
return;
}
try {
const machineGroupId = Object.keys(this.mainClass.machineGroups).length + 1;
this.mainClass.machineGroups[machineGroupId] = machineGroup;
} catch (error) {
this.logger.warn(`Skip machinegroup connnection: ${error.message}`);
}
machineGroup.emitter.on("totalFlowChange", (data) => {
this.mainClass.logger.debug('Total flow change of machineGroup detected');
this.mainClass.handleInput("parent", "totalFlowChange", data)}); //Geef nieuwe totale flow door aan valveGrouControl
this.logger.info(`MachineGroup ${machineGroup.config.general.name} registered successfully.`);
}
connectActuator(actuator, positionVsParent) { connectActuator(actuator, positionVsParent) {
if (!actuator) { if (!actuator) {
this.logger.warn("Invalid actuator provided."); this.logger.warn("Invalid actuator provided.");

View File

@@ -13,6 +13,7 @@ class movementManager {
this.speed = speed; this.speed = speed;
this.maxSpeed = maxSpeed; this.maxSpeed = maxSpeed;
console.log(`MovementManager: Initial speed=${this.speed}, maxSpeed=${maxSpeed}`);
this.interval = interval; this.interval = interval;
this.timeleft = 0; // timeleft of current movement this.timeleft = 0; // timeleft of current movement