added coolprop
This commit is contained in:
55
src/coolprop-node/test/R744.C..test.js
Normal file
55
src/coolprop-node/test/R744.C..test.js
Normal file
@@ -0,0 +1,55 @@
|
||||
const coolprop = require('../src/index.js');
|
||||
|
||||
describe('R744 (CO2) Real Values', () => {
|
||||
it('should calculate superheat correctly at -40°C saturation', async () => {
|
||||
const result = await coolprop.calculateSuperheat({
|
||||
temperature: -35, // 5K above saturation temp of -40°C
|
||||
pressure: 9.03, // saturation pressure at -40°C (from chart)
|
||||
refrigerant: 'R744',
|
||||
tempUnit: 'C',
|
||||
pressureUnit: 'bar'
|
||||
});
|
||||
|
||||
expect(result.type).toBe('success');
|
||||
expect(Math.abs(result.superheat - 5)).toBeLessThan(0.1); // Should be ~5K superheat
|
||||
});
|
||||
|
||||
it('should calculate subcooling correctly at 0°C saturation', async () => {
|
||||
const result = await coolprop.calculateSubcooling({
|
||||
temperature: -5, // 5K below saturation temp of 0°C
|
||||
pressure: 33.84, // saturation pressure at 0°C (from chart)
|
||||
refrigerant: 'R744',
|
||||
tempUnit: 'C',
|
||||
pressureUnit: 'bar'
|
||||
});
|
||||
|
||||
expect(result.type).toBe('success');
|
||||
expect(Math.abs(result.subcooling - 5)).toBeLessThan(0.1); // Should be ~5K subcooling
|
||||
});
|
||||
|
||||
it('should calculate zero superheat at saturation point', async () => {
|
||||
const result = await coolprop.calculateSuperheat({
|
||||
temperature: -20, // Exact saturation temperature
|
||||
pressure: 18.68, // Matching saturation pressure from chart
|
||||
refrigerant: 'R744',
|
||||
tempUnit: 'C',
|
||||
pressureUnit: 'bar'
|
||||
});
|
||||
|
||||
expect(result.type).toBe('success');
|
||||
expect(Math.abs(result.superheat)).toBeLessThan(0.1); // Should be ~0K superheat
|
||||
});
|
||||
|
||||
it('should calculate zero subcooling at saturation point', async () => {
|
||||
const result = await coolprop.calculateSubcooling({
|
||||
temperature: 10, // Exact saturation temperature
|
||||
pressure: 44.01, // Matching saturation pressure from chart
|
||||
refrigerant: 'R744',
|
||||
tempUnit: 'C',
|
||||
pressureUnit: 'bar'
|
||||
});
|
||||
|
||||
expect(result.type).toBe('success');
|
||||
expect(Math.abs(result.subcooling)).toBeLessThan(0.1); // Should be ~0K subcooling
|
||||
});
|
||||
});
|
||||
Reference in New Issue
Block a user